The Demonstration of Energy Efficiency Potential (DEEP) Project.

The Department for Energy Security and Net Zero (DESNZ) commissioned the Demonstration of Energy Efficiency Potential (DEEP) project, which ran from 2019 to 2024. It was one of the UK’s largest research projects into retrofitting solid walled homes. This case study sets out what DEEP found about solid wall insulation, retrofit risks and the accuracy of EPCs.

Why solid walled homes matter

Solid walled homes are among the least energy efficient in the UK, and the people living in them are more likely to be in fuel poverty. They also face higher risks of condensation, cold in winter and overheating in summer. However, solid wall insulation is costly, and it carries more risk of unintended problems than any other retrofit measure.

How the research worked

Leeds Beckett University led the project, supported by the University of Salford and Loughborough University. First, Leeds Beckett measured performance and risks before and after retrofitting 14 solid walled homes, then compared the results with modelled predictions. Next, Salford recreated one of the retrofits in its Energy House lab under controlled conditions. Finally, Loughborough modelled risks that the field studies could not observe.

What DEEP found

  • Solid wall insulation had by far the biggest impact. On its own, it cut heat loss by between 19% and 55%, equal to a 7% to 38% fall in fuel bills. By comparison, other single measures saved between less than 1% and 8% on bills.
  • Combining measures did even more. Draught proofing, loft or room in roof insulation, new windows and doors, floor insulation and solid wall insulation together cut whole house heat loss by up to 60%.
  • Costs were high and often underestimated. Solid wall insulation cost between £4,000 and £44,000. In addition, repairs and preparation added an average of 26% to retrofit costs.
  • EPCs overestimated heat loss by 42% on average. They also overpredicted retrofit savings by an average of 46%, known as the prebound effect.
  • Airtightness was hard to predict. Of 146 homes surveyed, 10% had excessive air leakage, and nobody could tell which ones without testing.

Reducing the risks

Piecemeal retrofits generally reduced condensation risk, but some risks remained where insulation had gaps. By contrast, following the whole house approach and closing those gaps brought risks down to acceptable levels. Similarly, solid wall insulation helped reduce overheating, although homes also needed extra ventilation and shading, especially in a warmer future climate.

What it means for retrofit

DEEP shows that better surveys before work starts would avoid many problems, for example by spotting earlier insulation, repair needs and airtightness issues. It also suggests that EPCs need better inputs and methods if policy is to rely on them.