Housing association Bromford Flagship and technology provider Senze, with support from Lloyds, tested monitoring technology in 121 homes. The aim was to measure how well each home actually holds heat, and then compare this with its modelled EPC data. This case study shows how large the thermal performance gap can be, and why it matters for retrofit decisions.
How the pilot worked
Senze sensors measured the thermal performance of each home in real time. Meanwhile, Lloyds commissioned The Good Economy to give an independent view of the pilot. In particular, it looked at the likely environmental, social and economic impacts, and what wider use of this technology could mean.
What the pilot found
On average, the pilot found a thermal performance gap of 25% between measured and modelled performance. Moreover, 11% of the homes lost more than double the heat their models predicted.
According to Bromford’s summary of the study:
- 64% of homes had a gap of more than 25%, either above or below what their EPC predicted
- 20% of homes had an inaccurate EPC rating, which changed whether they were recommended for retrofit to meet the proposed Minimum Energy Efficiency Standards
- a data led, more targeted approach to reaching EPC C could save up to £27,872 per home
Why it matters
If EPCs are wrong, retrofit money can go to homes that don’t need upgrades, while homes that do need help miss out. This matters even more as social landlords work towards EPC C by 2030 under the proposed standards. In contrast, measured data lets landlords target their spending at the homes that need it most.
“This study proves real-life data can lead to more targeted retrofit solutions.” David Partridge, Chairman and Co-founder, Senze
Understanding the performance gap
A home’s heat transfer coefficient (HTC) measures how fast it loses heat through its walls, roof, floors and windows. Usually, EPCs estimate this using a model. However, homes that look the same on paper do not always perform the same in reality. So, measuring real performance with smart meters, sensors or short tests can give a much more accurate picture.
Our report Retrofit Performance Data: Better Decisions and Outcomes explores these methods in more detail. You can also see how the government funded DEEP project found a similar gap.